Implication of Laser Technology Than That of Shape Memory Alloy [NiTinol] in Angioplasty
C. Anil Kumar, Y. Vijaya Kumar
Pages - 501 - 509 | Revised - 30-10-2009 | Published - 30-11-2009
Published in International Journal of Engineering (IJE)
MORE INFORMATION
KEYWORDS
Angioplasty, Laser technology, Restenosis, Metallosis, Excimer Laser
ABSTRACT
Modern Angioplasty is an alternative to bypass heart surgery because of safety and validity. As we know that the Heart diseases has risen to become that number of deaths in most of the developing or developed countries due to the high increase rates of obesity, drug dependence, and diabetes. Stents are used throughout the body but the most critical area being coronary arteries. Convention Material like Stainless Steel 316LN is used before, now a day’s Smart Materials like Nitinol is having wider application in Angioplasty. This paper presents the comparison and limitations of the Shape memory alloy [Nitinol] technology with that of Laser technology. The several materials used in angioplasty for stenting are Stainless steel 316LN, Titanium and Nitinol. Laser technology finds more beneficial due to its rapid growth in technology and also more advantageous because of the alloys used are resistant to corrosion, yet the corrosion occurs when two dissimilar surfaces are in contact and this happens in almost all alloys These devices have been used for only a few years and, although initial results look promising, long-term effects have not been fully investigated. It's important to note that, if restenosis recur there is no good method to simply remove the blockage, and follow-up treatments may require laser surgery or localized drug delivery using other angioplasty devices.
D. Tanase, B.P. Iliev, J.F.L. Goosen, Z. Chang, G.A.M. Pop, J.M.M. Verwiel,C.J. Slager, P.J. Trimp, L. Pakula, G.C.M. Meijer, P.J. French, Investigation of multi-sensor techniques for cardiac-output measurements in theintensive care” To be presented, IEEE-EMBS, Hawaii, May 2005. | |
D. Tanase, J.F.L. Goosen, P.J. Trimp, P.J. French, “Multi-parameter sensor system with intravascular navigation for catheter/guide wire application”, Sensors and Actuators A 97-98 (2002) pp116-124. | |
Gower MC, Rumsby PT, and Thomas DT, Novel Applications of Excimer Lasers for Fabricating Biomedical and Sensor Products, Bellingham, WA, International Society for Optical Engineering, vol 1835, pp 133–142, 1993 | |
J.F.L. Goosen, P.J. French and P.M. Sarro, “Pressure, flow and oxygen saturation on one chip for use in catheters”, Proceedings MEMS 2000, Miyazaki, Japan, January 2000, pp 537-540. | |
Pokora L, "Excimer Lasers and Their Applications in Industrial Technology and in Medicine," Opto-Electronics Rev, 1: 13–20, 1993. | |
Schaeffer R, "Laser Micromachining of Medical Devices," Med Plast Biomat, 3(3): 32–38, 1996. | |
Topaz O. Whose fault is it? Notes on "true" versus "pseudo" laser failure (editorial). Cathet Cardiovasc Diagn. 1995;36 :1-4. | |
Mr. C. Anil Kumar
Dr. M.G.R. Educational & Research Institute, - India
canilkumar71@yahoomail.com
Mr. Y. Vijaya Kumar
SBMJCE.Bangalore-562 112, - India
|
|
|
|
View all special issues >> | |
|
|